Which pump keeps your flow steady for hours? The syringe pump vs peristaltic pump question has no one winner.
The facts here come from DK INFUSETEK. Its pumps are for lab and industrial use, not medical use. Each number is for one model only.
Three things help you choose: accuracy, volume and pulsation. Pulsation is how much the flow surges.
The Main Points
Pulsation: Piston and peristaltic pumps both make the flow surge, says Infusetek. The CFCU-I aims for low-pulsation flow.
Tubing wear: Worn tubing lowers the flow. Then the flow cannot stay steady.
Finite syringe volume: A standard syringe pump stops when the syringe is empty. The continuous models keep going.
Pressure limit: The top pressure for both continuous models is 0.68 MPa.
Which Pump Fits Your Liquid, Flow and Precision Needs?
In the syringe pump vs peristaltic pump debate, DK INFUSETEK has a simple view. Syringe pumps are good for work that needs more precision and less surging. Peristaltic pumps are good for complex liquids and high flows. Check five things: the liquid, the flow, how much surging you can take, how long it runs and the pressure.

An Easy Way to Choose
-
Need precision and low pulsation? Pick a syringe pump.
-
Need complex liquids and high flow? Pick a peristaltic pump.
-
Need micro-liter flow that never stops? Pick a continuous flow syringe pump.
How Does Each Pump Move Liquid?
How a Syringe Pump Works
One kind of positive displacement pump is the syringe pump. Using a plunger that travels at a predetermined pace, it expels liquid. Typically, a lead screw is turned by a stepper motor. The plunger is moved along the syringe by the screw.
The speed of the plunger multiplied by the area of the syringe inside determines the flow rate. The ISPLab01-Pro site of Infusetek shows this formula.
How a Peristaltic Pump Works
By squeezing a flexible tube, a peristaltic pump moves fluid. Here is some broad context. This is not a claim made by Infusetek.
Syringe Pump vs Peristaltic Pump: Side-by-Side Comparison
Infusetek makes syringe pumps, so this syringe pump vs peristaltic pump table shows its view. If the site says nothing, the cell says so.
Comparison Table
|
Factor
|
Syringe pump (per DK INFUSETEK)
|
Peristaltic pump (per DK INFUSETEK)
|
|
Pulsation
|
Handbook: better for work that needs more precision and less surging. CFCU-I: low-pulsation, very steady flow
|
Constinfuse® article: has the same surging problem as piston pumps
|
|
Long-run flow stability
|
Continuous flow models are built for nonstop transfer
|
Flow drops as the tube wears and cannot stay steady for long
|
|
Fluids and flow size
|
Focus on micro-liter flow. CFSP-I/CU-I: 0.06 μL/min–70 mL/min
|
Handbook: ideal for complex liquids and high flows
|
|
Delivery limit
|
A standard model must stop when the syringe is empty. Continuous flow models do not stop
|
Not published by Infusetek
|
Dosing Accuracy: How Exact Are the Numbers?
A single model and one set of tests constitute each dosage accuracy number. It is not a good idea to compare outcomes from different models.
The "30% stroke rule" means that the plunger must travel at least 30% of its maximal stroke. That is the farthest it has traveled.
Accuracy by Model
|
Model
|
Stated figure
|
Condition
|
|
CFSP-I/CU-I
|
Stroke control error ≤ ±0.1%
|
Stroke ≥ 30% of max stroke
|
|
CFCU-I
|
Stroke control error ≤ ±0.1%
|
Stroke ≥ 30% of max stroke
|
|
ISPLab01-Pro (lab pump, for contrast)
|
Error ≤ ±0.3%
|
Stroke ≥ 30% of the 140 mm max (about 42 mm)
|
Infusetek gives no matching accuracy number for peristaltic pumps. Both continuous models list a dispensing volume of 0.1 μL–25 mL.
Low Flow Rates: What Does Syringe Size Change?
Syringe size decides how low and how high the flow can go. This matters most for low flow rates. The CFSP-I/CU-I runs from 0.06 μL/min to 70 mL/min. That number is for pure water. The inlet tube is under 1 m long and 1.6 mm wide inside.
The CFCU-I runs from 0.07 μL/min to 70 mL/min.
The lab model ISPLab01-Pro lists 0.008 nL/min–165.871 mL/min with all its syringes. An older Infusetek sheet says tube size, tube length and the liquid all change the flow.

Flow Range by Syringe Size (Both Continuous Models)
|
Syringe
|
Min flow
|
Max flow
|
|
50 μL
|
0.0625 μL/min
|
608.37 μL/min
|
|
100 μL
|
0.125 μL/min
|
1.21 mL/min
|
|
250 μL
|
0.3125 μL/min
|
3.04 mL/min
|
|
500 μL
|
0.625 μL/min
|
6.08 mL/min
|
|
1.0 mL
|
1.25 μL/min
|
12.16 mL/min
|
|
2.5 mL
|
3.125 μL/min
|
30.41 mL/min
|
|
5.0 mL
|
6.25 μL/min
|
60.83 mL/min
|
|
10 mL
|
12.5 μL/min
|
70.00 mL/min
|
|
25 mL
|
31.25 μL/min
|
55.00 mL/min
|
Pulse-Free Flow: Does Pulsation Change Your Results?
Pulsation is flow that goes up and down. Infusetek says every piston move makes it. It says peristaltic pumps have the same problem.
People search for pulse-free flow. Infusetek uses the word "low-pulsation." It never says zero pulsation. This article does the same.
The CFCU-I has two actuators that work together. Its own compensation and calibration method backs them up. The site says this gives a smooth, steady flow.
Where Uneven Flow Causes Trouble
Electrospinning: The flow rate of the polymer solution sets the fiber thickness, structure and strength.
Precision coating: Uneven flow can leave streaks and uneven thickness.
Peristaltic Pump Tubing: What Happens Over Time?
Tubing Wear and Changing Flow
Worn tubing lowers the flow rate, says Infusetek. Then the flow cannot stay steady over a long run. The handbook says the tubing must be replaced often because it wears out with long use.
Fluid Contact: What Touches Your Liquid
Fluid contact is different in each design. In a peristaltic pump, the liquid stays inside the tube. The handbook calls this a plus, since the pump body does not touch the liquid.
Syringe pump parts that touch the liquid, as listed on the site:
Both continuous models: borosilicate glass barrel and PTFE plunger seal.
CFSP-I/CU-I valve: PCTFE body with a PTFE element.
CFCU-I valve options: 3-way ceramic, PTFE or PEEK.
Infusetek says plain PTFE valves wear out fast with liquids that carry particles, such as graphene and carbon powder. So it built ceramic alumina valves.
Finite Syringe Volume: What Happens When It Runs Out?
A syringe holds only so much liquid. So a standard syringe pump can only run for so long. Infusetek says it must stop when the syringe is empty. A continuous flow model does not stop. Both continuous models take syringes from 50 μL to 25 mL.
Infusetek's Constinfuse® article talks about older push-pull pumps. They fixed the stopping problem. But they could not keep the flow steady for long.
What About Continuous Recirculation?
Continuous recirculation means liquid goes round and round in a closed loop. Infusetek gives no recirculation specs.
It lists a "continuous transferring" mode (CFSP-I/CU-I) and a "Continuous Transfer" mode (CFCU-I). Planning a loop? Ask the team first.
Back Pressure: How Much Can the Pumps Take?
Back pressure is the push-back from your system against the pump. Both continuous models have a top liquid-path pressure of 0.68 MPa.
Need more? Contact Infusetek. The CFCU-I lists optional upgrades. Check this number against your own system first. Infusetek gives no pressure numbers for peristaltic pumps.
How Do You Pick the Right Pump?
Use these tips to settle the syringe pump vs peristaltic pump choice for your own work.
When a Peristaltic Pump Fits
The Infusetek handbook says peristaltic pumps are ideal for complex liquids and high flows.
Where Syringe Pumps Are Used
Infusetek lists microfluidics, flow chemistry, battery, coating, electrospinning and dispensing. Two cases from its site:
Heidelberg University's IMSEAM microfluidic station uses the ISPLab01. It moves deionized water, polystyrene beads and cell solution.
ClaremontBio recommends the DK INFUSETEK SPLab/ISPLab series for its Automated Lateral Flow Reagent Dispenser.
Five Questions to Ask
-
How complex is the liquid?
-
What flow range do you need?
-
How much surging can your process take?
-
Will it run longer than one syringe holds?
-
What is your system pressure?
For control, the continuous models offer RS232/RS485 (Modbus RTU) and external switch signals. The CFSP-I/CU-I also has a 4.3-inch screen.

Four Mistakes to Avoid
Comparing accuracy numbers across different models.
Skipping the pressure check.
Forgetting that tube length, tube size and the liquid change the flow.
Thinking "continuous transfer" is the same as recirculation.
How Do the Two Continuous Flow Models Differ?
The modes and valve options are not the same. Read each column on its own.
Spec Table
|
Spec
|
CFSP-I/CU-I
|
CFCU-I
|
|
Flow range
|
0.06 μL/min–70 mL/min
|
0.07 μL/min–70 mL/min
|
|
Dispensing volume
|
0.1 μL–25 mL
|
0.1 μL–25 mL
|
|
Stroke control accuracy
|
≤ ±0.1% (stroke ≥ 30%)
|
≤ ±0.1% (stroke ≥ 30%)
|
|
Working modes
|
4: Continuous transferring; Fixed volume measurement; Dispensing; Timing start/stop
|
3: Continuous Transfer; Volumetric Metering; Timed Metering
|
|
Max liquid-path pressure
|
0.68 MPa
|
0.68 MPa (optional upgrades)
|
|
Valve
|
3-port 120° valve; PCTFE body, PTFE element
|
3-way ceramic, PTFE or PEEK
|
|
Syringe sizes
|
50 μL–25 mL
|
50 μL–25 mL
|
|
Communication
|
RS232/RS485, Modbus RTU
|
RS232/RS485, Modbus RTU
|
Who Is DK INFUSETEK?
DK INFUSETEK is the brand of Duko Industrial Technology (Shanghai) Co., Ltd. Its main office and R&D center are in Shanghai. Its production base is in northern China.
It designs, makes and customizes devices for micro-fluid handling. That means handling tiny amounts of liquid. Address: No.355, Building B, Hongqiao World Center, Yinggang Dong Road, Qingpu District, Shanghai 201700, China. Email: sales@infusetek.com. For delivery time, please contact the team.
FAQs
Is a syringe pump better than a peristaltic pump?
In the syringe pump vs peristaltic pump contest, no pump wins every time. Syringe pumps are good for precise work with less surging. Peristaltic pumps are good for complex liquids and high flows, says DK INFUSETEK. Pick by your liquid, your flow and how precise you need to be.
Which pump has less pulsation?
Syringe pumps, says Infusetek, are good for work that needs less surging. The CFCU-I is called low-pulsation. Peristaltic pumps have the same surging problem as piston pumps. No pump is said to have zero pulsation.
Why does peristaltic pump tubing change the flow rate?
Worn tubing lowers the flow rate, says Infusetek. Over a long run, the flow cannot stay steady. The handbook adds that the tubing must be replaced often after long use.
Can a syringe pump run nonstop with a finite syringe volume?
Yes, continuous flow models can. A standard syringe pump must stop when the syringe is empty. The CFSP-I/CU-I and CFCU-I are built to keep the flow going without a break.
How accurate is the CFSP-I/CU-I?
Its stroke control error is ≤ ±0.1% when the stroke is at least 30% of the maximum stroke. This number is for that model and that setup only.
What is the maximum pressure?
The top liquid-path pressure is 0.68 MPa on both continuous models. For more pressure, contact Infusetek. The CFCU-I lists optional upgrades.
Conclusion
The syringe pump vs peristaltic pump choice depends on your liquid, flow, run time and pressure. Pick the one that fits your work best. Use a syringe pump when you need precision and less pulsing. Use a peristaltic pump for complex liquids and high flow.
Use a continuous flow syringe pump when the flow must not stop. For that, try Duko Industrial Technology (Shanghai) Co., Ltd. Its continuous flow pumps list clear flow, accuracy and pressure numbers. To learn more, visit infusetek.com or email sales@infusetek.com.